About LEDask
Free, independent LED lighting calculators and guides.
Our Mission
We believe everyone deserves access to clear, unbiased information about LED lighting. LEDask's mission is to help homeowners and businesses make informed decisions that save money, reduce energy consumption, and protect our planet — with free tools whose formulas you can check.
Who Writes LEDask
LEDask is run by Hommer Zhao, its founder and general manager.

Hommer Zhao
Founder & General Manager
Runs the siteHommer Zhao is the founder and general manager of LEDask. He runs the site and oversees the calculators, the checks of their formulas and reference values against published engineering data, and the guides across the site.
How the tools are kept accurate
- Calculator formulas use standard engineering equations (e.g. R = (Vs − Vf) / I, V = I × R).
- Reference values (copper resistance per 1000 ft, AWG sizes, LED forward voltages) are taken from published engineering data.
- Every English calculator page has a "How this calculator works" section with its formula, a worked example and its assumptions, so you can check the math yourself.
Why LEDask exists
Most lighting questions come down to a few numbers: how many lumens a room needs, which resistor an LED needs, how much a wire run drops the voltage, and what a bulb costs to run. Many calculators give an answer without showing the formula or the assumptions behind it. LEDask shows both, so you can check the result before you buy parts or wire anything.
Data sources and assumptions
- Standard resistor values
- IEC 60063 E24 series. The LED resistor calculator rounds up to the next E24 value so that, at the supply voltage and forward voltage you enter, the calculated current does not exceed your target. Real supplies, LEDs and resistors have tolerances, so check the worst case (highest supply voltage, lowest forward voltage) for tight designs.
- Foot-candles and lux
- NIST SP 811 conversion: 1 fc = 10.7639 lx.
- Copper wire resistance (AWG)
- Standard solid annealed copper values at 20 °C (68 °F), e.g. 14 AWG = 2.525 Ω per 1000 ft. Hot conductors have more resistance, so real voltage drop can be higher.
- Lighting layouts
- The IES lumen method (lumens = foot-candles × area ÷ (CU × LLF)) in the foot-candle calculator. The room lighting calculator is a quicker estimate without CU/LLF and gives lower numbers.
- Energy and CO2
- kWh = watts × hours ÷ 1000. CO2 uses a flat 0.43 kg per kWh as a planning figure, not your local grid's value. For comparison, EPA eGRID (2023 data) lists the U.S. average at 767.209 lb/MWh, which is 0.348 kg per kWh.
- LED equivalents
- Rough wattage ratios (an LED at about 15% of an incandescent's watts), in line with the U.S. Department of Energy's statement that LEDs use up to 90% less energy than incandescent bulbs. Compare lumens on the box before you buy.
Results are estimates for planning. For mains wiring, follow your local electrical code and use a licensed electrician.
What We Offer
Free Calculators
18 calculators and 3 guides for lighting and wiring decisions
Practical Guides
Plain-language LED lighting explanations
Checkable Math
Formulas and reference values you can verify
33 Languages
Available worldwide, no sign-up needed
18
Free Calculators
33
Languages
100%
Free — No Sign-up
clooms
Operated by
Ready to Start Saving?
Use our free tools to calculate your potential savings today.