CRI Guide
Understanding Color Rendering Index and why it matters for your lighting.
1Select Your Space
2CRI Recommendation
Minimum CRI
90
Ideal CRI
95+
Why this matters:
Accurate food colors for safe preparation
CRI Quality Scale
Shopping Tip
Look for "CRI" or "Ra" on LED packaging. If it is not listed, you cannot tell from the box; check the datasheet or ask the seller. Products that reach 90+ or 95+ CRI usually say so on the packaging.
How to use this guide
- Pick a category and a room. The guide shows a minimum CRI, an ideal CRI and why it matters there.
- Compare with the CRI (Ra) printed on the bulb or fixture datasheet.
- For colour-critical rooms, also check R9 (saturated red), which Ra does not include.
- When two products list the same CRI, compare R9 or the TM-30 fidelity (Rf) and gamut (Rg) values if the datasheet gives them, and view the lamps side by side on the actual materials if you can.
What is the Color Rendering Index (CRI)?
CRI describes how faithfully a light source shows the colours of objects compared with a reference light of the same colour temperature, on a scale that tops out at 100. The general index, Ra, is the average of eight test colour samples, R1 to R8.
How is CRI measured?
The spectrum of the lamp is used to calculate how each test colour sample would look under it and under the reference source (CIE 13.3). The colour shift for each sample gives a special index (R1 to R14 in CIE 13.3; many datasheets also list an R15 added later), and Ra is the mean of the first eight. Saturated red (R9) is not part of Ra, which is why two lamps with the same CRI can show reds very differently.
What CRI is good enough?
It depends on the room. This guide uses a minimum of 80 for a living room and 90 for a kitchen, and asks for more where colour decisions are made. These are this guide's planning targets, not requirements from a standard; the full list is in the table below.
Is CRI the same as colour temperature?
No. Colour temperature (in kelvin) says whether the light looks warm or cool; CRI says how accurately it shows colours. A 2700 K lamp and a 5000 K lamp can both be CRI 90.
Worked example: two lamps with the same CRI and very different reds
Computed by this calculator's own code (method v1.1.0) when this page was built on 2026-11-20.
| Lamp A, R1 to R8 (hypothetical) | 92, 93, 90, 89, 91, 90, 88, 87 |
|---|---|
| Lamp A, R9 (hypothetical) | 62 |
| Lamp B, R1 to R8 (hypothetical) | 96, 95, 88, 90, 92, 89, 86, 84 |
| Lamp B, R9 (hypothetical) | 18 |
| Lamp A: Ra = mean of R1 to R8 | 90.0 |
|---|---|
| Lamp B: Ra = mean of R1 to R8 | 90.0 |
| Printed on both boxes | CRI 90 |
| R9 (not part of Ra) | 62 vs 18 |
The R values are made up for this illustration and are not measurements of any product. They show that Ra is only an average of eight pastel test colours: both lamps round to the same CRI, yet lamp B would render saturated reds (skin tones, meat, red fabrics) much less faithfully. This is why step 3 above says to check R9 on the datasheet for colour-critical rooms; the selector itself only shows CRI targets.
All rooms in this guide
| Category | Room | Minimum CRI | Ideal CRI | Priority |
|---|---|---|---|---|
| Home | Living Room | 80 | 90+ | Moderate |
| Home | Kitchen | 90 | 95+ | Important |
| Home | Bathroom | 90 | 95+ | Critical |
| Home | Bedroom | 80 | 90+ | Moderate |
| Home | Home Office | 85 | 90+ | Important |
| Home | Closet/Wardrobe | 90 | 95+ | Important |
| Retail / commercial | Clothing Store | 90 | 95+ | Critical |
| Retail / commercial | Jewelry Store | 95 | 97+ | Critical |
| Retail / commercial | Grocery/Food | 90 | 95+ | Critical |
| Retail / commercial | Electronics | 80 | 85+ | Moderate |
| Retail / commercial | Furniture Store | 90 | 95+ | Important |
| Hospitality | Restaurant Dining | 90 | 95+ | Critical |
| Hospitality | Hotel Lobby | 85 | 90+ | Important |
| Hospitality | Hotel Room | 85 | 90+ | Moderate |
| Hospitality | Bar/Lounge | 80 | 85+ | Moderate |
| Hospitality | Spa/Wellness | 85 | 90+ | Important |
| Healthcare | Operating Room | 95 | 97+ | Critical |
| Healthcare | Examination Room | 90 | 95+ | Critical |
| Healthcare | Dental Office | 95 | 97+ | Critical |
| Healthcare | Patient Room | 85 | 90+ | Important |
| Healthcare | Pharmacy | 90 | 95+ | Important |
| Art and display | Art Gallery | 95 | 97+ | Critical |
| Art and display | Museum | 95 | 97+ | Critical |
| Art and display | Photography Studio | 95 | 97+ | Critical |
| Art and display | Print Shop | 95 | 97+ | Critical |
| Art and display | Design Studio | 90 | 95+ | Important |
Planning guidance used by this site, not requirements from a building code or standard. The same values drive the selector above.
Assumptions and limits
- The minimum and ideal values are planning guidance used by this site, not requirements from a building code or standard.
- CRI is one number from eight test colours. Two lamps with the same CRI can still look different.
Sources
- CIE 13.3, Method of measuring and specifying colour rendering properties of light sources (definition of Ra).