Wire Gauge Calculator

Find the right wire size for your LED project based on current and distance

1Project Requirements

Total current draw of your load in amps

Distance from power supply to load

3% recommended for LED strips, 5% for general use

2Recommended Wire Size

10 AWG

Recommended Wire Gauge

2.1% voltage drop

Max Rated Current

30 A

Wire Diameter

2.588 mm

Wire Gauge Comparison

24 AWG
53.5%2.1A max
22 AWG
33.6%3A max
20 AWG
21.1%5A max
18 AWG
13.3%7A max
16 AWG
8.4%10A max
14 AWG
5.3%15A max
12 AWG
3.3%20A max
10 AWGBest Choice
2.1%30A max

AWG Quick Reference

Lower AWG numberThicker wire, more current
Higher AWG numberThinner wire, less current

Why Wire Gauge Matters

Choosing the correct wire gauge is critical for safety and performance. Wire that's too thin for the current load will heat up, waste energy, and can be a fire hazard. For LED installations, undersized wire also causes voltage drop, leading to dimmer LEDs at the end of long runs.

How This Calculator Works

This calculator considers your current requirements, wire length, and acceptable voltage drop to recommend the smallest (most economical) wire gauge that meets your needs. It also ensures the wire's ampacity rating exceeds your load current for safe operation.

Wire Selection Tips

  • •Always round up to a larger wire gauge (smaller AWG number) when in doubt - it's safer and allows for future expansion
  • •Consider using stranded wire for flexibility in LED installations, especially where the cable needs to bend
  • •For outdoor or high-temperature environments, derate wire capacity by 20% or more
  • •Copper is preferred for LED projects due to its lower resistance, but aluminum can work for longer, high-current runs where weight matters

How this calculator works

  1. For each gauge from 24 AWG to 10 AWG, work out the voltage drop over the round-trip length.
  2. Keep the gauges whose drop stays within your limit and whose ampacity covers the current.
  3. Recommend the thinnest gauge that passes both checks.

Worked example: 5 A at 12 V over 25 ft, 3% limit

Computed by this calculator's own code (method v1.0.0) when this page was built on 2026-11-20.

Inputs
Current5 A
One-way length25 ft
Supply12 V
Max drop3%
Wirecopper
Results
Recommended gauge10 AWG
Drop with that gauge0.250 V
Percent drop2.08%

14 AWG would carry the current but drops 5.26%, above the 3% limit.

Copper wire reference used by this calculator

GaugeΩ per 1000 ft at 20 °C≈ Ω per 1000 ft at 75 °CAmpacity used (A)
24 AWG25.67031.2192.1
22 AWG16.14019.6293
20 AWG10.15012.3445
18 AWG6.3857.7657
16 AWG4.0164.88410
14 AWG2.5253.07115
12 AWG1.5881.93120
10 AWG0.9991.21530

75 °C column estimated with α = 0.00393/°C. Ampacity values are this tool's own assumptions and are not taken from the NEC or any other code.

Assumptions and limits

  • Resistance is for solid copper at 20 °C. In a hot ceiling or conduit, size up if you are close to the limit.
  • Aluminum is approximated as 1.6 × copper resistance and 0.8 × copper ampacity.
  • For mains (120/230 V) branch circuits, your local electrical code sets the minimum wire size, not this tool.

Sources

  • ASTM B258 (AWG diameters) with the resistivity of annealed copper (IACS); values are for solid copper at 20 °C.
  • Copper temperature coefficient of resistance: 0.00393 per °C at 20 °C.